13.5.31. Check and adjustment of a starting position of the movable panel of a roof
|
- Close the movable panel.
- Remove a forward ceiling plafond, address the Section Removal and installation of plafonds of internal lighting.
- Unscrew screws of fastening and remove the electric motor of the movable panel.
- Do not disconnect electric wires of the electric motor.
- Include ignition.
- Establish by the rotary switch situation "The Roof Is Closed". At the same time the electric motor works automatically and stops in zero situation.
- In this situation install the electric motor at the closed roof and fix it.
- Establish a forward plafond.
|
|
Check of a starting position of a kulisny guide
|
|
The starting position can be checked by means of a pocket mirror and a pocket lamp at the installed movable panel. |
|
- Remove side slips at the left and on the right, address appropriate section.
|
- Open and again close the movable panel.
|
- Shift the ceiling panel completely back.
|
- Put a pocket mirror on the movable panel and check a starting position. At the correct installation a rectangular groove in the mechanism of promotion of a kulisny guide (1) has to coincide with a groove (an arrow on an accompanying illustration). Otherwise make adjustment.
|
|
|
Installation of the directing coulisse in a starting position
|
- Remove the movable panel.
- Remove the panel electric motor.
- Remove side slips, address appropriate section.
- Displace kulisny guides (1) on both sides from back situation forward.
- Install a rectangular groove in the mechanism of promotion of a kulisny guide (1) so that it coincided with a groove (shooter) on the directing tire (2) panels of a ceiling. Thus the starting position of the directing coulisse is established.
- Install the electric motor of the movable panel in a starting position.
- Establish side slips.
|
|