13.5.31. Check and adjustment of a starting position of the movable panel of a roof

 PERFORMANCE ORDER

  1. Close the movable panel.
  2. Remove a forward ceiling plafond, address the Section Removal and installation of plafonds of internal lighting.
  3. Unscrew screws of fastening and remove the electric motor of the movable panel.
  4. Do not disconnect electric wires of the electric motor.
  5. Include ignition.
  6. Establish by the rotary switch situation "The Roof Is Closed". At the same time the electric motor works automatically and stops in zero situation.
  7. In this situation install the electric motor at the closed roof and fix it.
  8. Establish a forward plafond.

Check of a starting position of a kulisny guide

 PERFORMANCE ORDER

The starting position can be checked by means of a pocket mirror and a pocket lamp at the installed movable panel.

  1. Remove side slips at the left and on the right, address appropriate section.
  1. Open and again close the movable panel.
  1. Shift the ceiling panel completely back.
  1. Put a pocket mirror on the movable panel and check a starting position. At the correct installation a rectangular groove in the mechanism of promotion of a kulisny guide (1) has to coincide with a groove (an arrow on an accompanying illustration). Otherwise make adjustment.

Installation of the directing coulisse in a starting position

 PERFORMANCE ORDER

  1. Remove the movable panel.
  2. Remove the panel electric motor.
  3. Remove side slips, address appropriate section.
  4. Displace kulisny guides (1) on both sides from back situation forward.
  5. Install a rectangular groove in the mechanism of promotion of a kulisny guide (1) so that it coincided with a groove (shooter) on the directing tire (2) panels of a ceiling. Thus the starting position of the directing coulisse is established.
  6. Install the electric motor of the movable panel in a starting position.
  7. Establish side slips.