13.5.25. Removal and installation of a door of a back (Station wagon)
|
- Disconnect a negative cable (-) of the rechargeable battery.
|
|
- Remove facing of a door of a back, address the Section Removal and installation of facing of a door of a back (Station wagon).
- Disunite sockets of heating of back glass and screen wiper, and also the uniform lock. Disconnect a hose of a washer of back glass.
|
|
It is necessary for simplification of installation will fix a cord which after a pulling of wires remains in a cover on the ends of a wire. |
|
Surely ask the assistant to take a back door before removing a gas-filled emphasis. Otherwise the door can fall since it cannot hold only the account of one damper. |
|
- Disconnect above a gas-filled emphasis (1). For this purpose raise the screw-driver a lock spring (3) a little and remove an emphasis from a spherical pin (2). Remove the second emphasis in the same way.
|
|
- Uncover loops and the guide for a cable located at a loop.
- For the subsequent installation: Mark with a felt-tip pen the provision of loops of a door of a back.
|
- Turn out screws (arrows on an accompanying illustration) from a back door at the left and on the right.
|
|
- Remove a door by means of the assistant.
|
|
Installation
|
- Establish a door by means of the assistant on loops. Expose an old door at the same time on earlier executed tags.
- Screw screws at the left and on the right.
- Establish a gas-filled emphasis on a spherical support and insert a lock ring. In the same way establish the second emphasis.
- Weaken a lock clamp, close a door and adjust it in relation to adjacent elements.
- Tighten screws the moment of 21 Nanometer.
- Further installation is carried out in the sequence, the return to removal.
- Attach a negative cable (-) of the rechargeable battery.
|
|
Back door: Check/adjustment
|
- Check gaps in interface of a door of a back to adjacent elements of a body. Gaps on all perimeter have to be uniform. The door has to coincide with side elements of a back part of a body. Over a roof the door should not act more than 0.5 mm.
|
- Turn off nuts (1) and (3) so that the clamp of the lock (2) could be displaced.
|
|
|
The pad (an arrow on an accompanying illustration) on a clamp shows back. |
|
- Uncover (1) on the left and right emphasis, and install the adjusting screw (2), having turned it counterclockwise, in situation "0".
|
|
- Close a door and press it on 2 mm into a body. Open a door and tighten nuts the moment of 21 Nanometer. The door has to be closed on the lock easily and not have a side play. Check gaps.
|
- Adjust the provision of the left and right emphasis so that the closed door had no side play. For this purpose put a little plasticine on an emphasis and close a door. It is possible to judge by a print of plasticine whether the door is correctly adjusted
|
- Establish on a cover emphasis.
|
|